Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Fixed 'out-of-memory' problem while saving oxg file
  • Fixed automatic glue detection / voxel QC crash for non-tringulated immersion cube models
  • Fixed autoplotting algorithm (enabled preprocessing and escaped 'unexpected error' for some GPUs)
  • Other minor fixes 
  • Support of voxel QC tools on not less then 2 Gb video card (in so called, 'demo resolution')
  • Autoplotting and voxel QC settings in Oxygen GUI

...

The resolution of voxel inclusions in demo mode is two times smaller than the resolution of inclusions in real mode. In these pictures (top - demo resolution, bottom - real resolution) you can see the difference between accuracy of these two modes. The accuracy of small inclusions is mostly affected by in demo resolution (one-voxel inclusion might turn into two-voxel inclusion):

...

In this version of Oxygen HIG we added a settings dialog where you may tune autoplotting and voxel QC tools. To launch the dialog click on the settings icon nead near 'Find inclusions automatically' button:

...

At the moment you may tune two settings for autoplotting and one for voxel QC tools. These settings are stored in Windows registry and all the applied settings will be the same for all futher program launches (even after Windows reboot). So before every launch of autoplotting or voxel QC, please, check the currently used settings.

...

  • Crack autoplotting. If this checkbox is not checked, then the following autoplotting will skip the crack autoplotting procedure. By default we recommend to check this checkbox. You may uncheck it in case when you see that there are too many big inclusions or there are no any cracks in rough. In these cases the probability of good crack processing is small, and the total autoplotting time increases if you enable crack autoplotting. In case of big inclusions these cracks might be combined with other big inclusions - crack autoplotting works well only in case of isolated flat cracks. So it would be better to isolate this crack from big inclusions on at voxel QC stage. As for 'no cracks' case, all the time of crack detection autoplotting will be wasted (because there are no cracks at all).
  • Automatic glue detection. Unchecking this checkbox you is the way to turn off the automatic glue detector during autoplotting. You may use it in some critical case, described here (note that from this moment you have no need to manipulated with hardcoded xml-files to do this). By default we recommend to check this checkbox.

...

  • Use demo resolution. As it was described in chapter 'Demo resolution for voxel QC tools', demo resolution is automatically enabled for video cards with less then 3 Gb memory. This checkbox gives you an opportunity to use demo resolution on powerful videocard with 3 Gb memory. This feature is useful in sutuation when you want to do small changes in voxel QC mode quickly. Voxel QC tools in demo resolution work faster than in real resoltionresolution. On the other hand, the precision of voxel QC tools in real resolution is higher (in by 2 times) than in demo one. So use demo resolution in case you do not need too much accuracy. To launch voxel QC tools in demo resolution, check this checkbox and launch voxel QC tools.

...