Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Hardware configuration storage logic has changed.
The camera-related details which were previously stored together with other parameters at HPODrivers.ini have been moved to hws.xml.
The update of the configuration files will occur automatically on the first launch of the program. At that, the following popup message will appear:

Scan & Build

Refinement of crown and pavilion against Reflect data is now controlled by different buttons and may be run separately.
The buttons are located at the lower part of the Scan panel, and only visible when the panel is set to Advanced mode.

...

Image Removed

...

After crown refinement

Image Removed

...

After pavilion refinement

...

Image Removed

...

Image Removed

...

Image Removed

Info
Previously both buttons initiated refinement against all Reflect data

...

Image Removed

...

    • Add edges with high precision Image Removed produces an edge located as close as possible to the user's input;
    • Add edges with low precision Image Removed treats the user's input as a vague hint, so the resulting refined edge may appear some distance away.

...

After refinement (high precision)

...

Image Removed

...

After refinement (low precision)

...

Image Removed

...

Image Removed

...

Image Removed

...

Image Removed

...

Note
Note that in both cases the refinement still can affect multiple other edges, not necessarily limited to the affected facet.

Interface

...

  1. Scanning (related to the stone properties entered before scanning);
  2. Automatic Actions (related to the actions performed after scanning, including report preparation and model export);
  3. Reports (related to the configurable report buttons).
    Image Removed

Exporting model is added to the context menu, both for the scans and recut solutions.

...

Image Removed

...

Image Removed

Upon pressing, you will be prompted to specify file name, location, format (type), and basis. The possible export formats are:

  • ASCII
  • STL (text)
  • STL (binary)
  • DMC
  • GEM

The possible basis options are:

  • Report (the model is oriented in the standard way, with first facet at zero azimuth).
  • Scanner (the model is oriented exactly as scanned).
    Image Removed
Info
Previously the Export model option was accessible via the Export model button on the right panel.

...

Smart Recut

  1. SmartRecut algorithm is improved, which has led to a considerable speed up in case of stones with cavities.

    Sample Base 1 (no cavities):

    SmartRecut VersionAvg. Time, sec
    1.10.4.231.42
    1.10.4.2632.21

    Sample Base 2 (with cavities):

    SmartRecut VersionAvg. Time, sec
    1.10.4.250.59
    1.10.4.2640.37
    Expand
    titleClick to see the computer configuration...

    Computer configuration:

    ProcessorIntel( R ) Core(TM) i7-4770K CPU @ 3.50GHz, Frequency: ~3497 MHz.
    Logical processors8
    Operating systemMicrosoft Windows 10 Pro 10.0.14393 Build 14393
    Total Visible Memory Size

    32710 MB

    Free Physical Memory29871 MB
  2. Smart Recut may now be applied to any of the multiple models inside of a Rough stone , in order to improve that model while respecting the borders of other models.
    See the example below: two Round brilliants are allocated in a rough stone using Cascade 2M algorithm in Pacor Client. Then the model is imported to HPOxygen, and the larger solution is used as a starting point for Smart Recut. Note that the Smart Recut solution is bigger than the original, yet still fits in the rough stone and remains outside of the other allocated brilliant.

    Image Modified

    Before Smart RecutAfter Smart Recut

    Image Modified

    Image Modified

Note
The models with multiple brilliants allocated inside a rough stone can't be produced by HPOxygen, and have to be imported from elsewhere.

...

The users with access to Facetware optimization feature may use another GIA-based appraiser with tightened limits GIA Facetware (Safe) which allows optimization.

Scan & Build

  1. Manually added edges are now available in two options: high and low reliability.
    Image Added
    The users are advised to choose one depending on their confidence in the position of the missing edge.
    The program, in turn, uses the degree of reliability to determine the extent to which the added edge can be altered during the refinement:
      • Add edges with high precision Image Added produces an edge located as close as possible to the user's input;
      • Add edges with low precisionImage Added treats the user's input as a vague hint, so the resulting refined edge may appear some distance away.
      Before refinement

      After refinement (high precision)

      Image Added

      After refinement (low precision)

      Image Added

      Image Added

      Image Added

      Image Added

      Note the light-green added edge.Note the refined model (cyan contours) laid over the original model (dark-green contours with light-green added edge).

     

    Note
    Note that in both cases the refinement still can affect multiple other edges, not necessarily limited to the affected facet.
  2. Refinement of crown and pavilion against Reflect data is now controlled by different buttons and may be run separately.
    The buttons are located at the lower part of the Scan panel, and only visible when the panel is set to Advanced mode.

    Image Added

    Before refinement

    After crown refinement

    Image Added

    After pavilion refinement

    Image Added

    Image Added

    Image Added

    Image Added

    Info
    Previously both buttons initiated refinement against all Reflect data

Interface

  1. Exporting model is added to the context menu, both for the scans and recut solutions.

    For scansFor solutions

    Image Added

    Image Added

    Upon pressing, you will be prompted to specify file name, location, format (type), and basis. The possible export formats are:

    • ASCII
    • STL (text)
    • STL (binary)
    • DMC
    • GEM

    The possible basis options are:

    • Report (the model is oriented in the standard way, with first facet at zero azimuth).
    • Scanner (the model is oriented exactly as scanned).
      Image Added
    Info
    Previously the Export model option was accessible via the Export model button on the right panel.
  2. Settings are reorganized into tabs as follows:
    1. Scanning (related to the stone properties entered before scanning);
    2. Automatic Actions (related to the actions performed after scanning, including report preparation and model export);
    3. Reports (related to the configurable report buttons).
      Image Added

  3. Photo view now displays the same model which is selected in the list of models. Previously it used the Main scan, regardless of the selection.
  4. Manual editing functionality is blocked unless the Main scan is selected. (See Models management for more details on Main scan).
    Image Added

Bugfixes

  1. Export of STL solutions in scanner basis is fixed.
  2. Occasional incorrect highlighting of problem-causing edges upon clicking on the corresponding lines in Model Building Info is fixed.
  3. Duplicate appearance of GIRDLE_INTERNAL_ANGLE_DEG_1 and other similar parameters in Export report data for Princess cut is fixed.
  4. Model Building Info (MBI) quality estimates are now correctly passed on to Export report data.
  5. Girdle for Octagon brilliant models is now built by the same method as for Round brilliant.
  6. Girdle height calculation for stones with extra girdle facets is fixed.
  7. Girdle bezel height statistics for 10x brilliant is fixed.
  8. Girdle bone symmetry grade is now correctly passed on to the reports. Previously a copy of girdle bezel grade was mistakenly reported instead.
  9. Bug that occasionally caused crash in the algorithm of facet type detection for rounded fancies is fixed.
  10. Corrected mass with 2 and 4 significant decimal digits (bookmarks CORRECTED_MASS_2 and CORRECTED_MASS_4, respectively) is now correctly passed on to the I3D Polish reports and I3D Comparative reports.
  11. Scale weight below 1 ct can now be entered without the leading zero (as ".545" instead of "0.545"; previously this was not interpreted correctly).

...