...
Label report is also enhanced with a similar control.
Lower Facet Length for Cushion
Lower Facet Length parameter is added for Cushion cuts.
...
Reported in | Section | Values | Units | Bookmarks |
---|---|---|---|---|
Full Report for Cushion | Main Parameters | Avg, Min, Max, Dev at each direction | Both %(diameter) and mm |
|
Detailed Parameters | Individual values (2 at each direction) | Both %(diameter) and mm | LOWER_FACET_LENGTH_0_1, LOWER_FACET_LENGTH_0_2, LOWER_FACET_LENGTH_90_1, LOWER_FACET_LENGTH_90_2, LOWER_FACET_LENGTH_180_1, LOWER_FACET_LENGTH_180_2, LOWER_FACET_LENGTH_270_1, LOWER_FACET_LENGTH_270_2 |
Miscellaneous
- Tolerance thresholds (modelEps, girdleEps) are now correctly interpreted during import of models from HP Pacor.
Usage of non-default values of these thresholds in HP Pacor could lead to different model built from the same contours, as compared to HPOxygen. - Inclusion clarity can now be set in HPO.
Bugfixes
...
Missing values for Cushion cuts (measurements # 3 and 4 for Crown Main Width angle and Crown Main Length angle) are added to the reports.
Crown Main Width and Crown Main Length facets for Cushion
For a non-standard Cushion cut having four Crown Main Width and four Crown Main Length facets, all four individual measurements for their slopes, azimuths, and heights are now reported.
...
Reported in | Section | Values | Units | Bookmarks |
---|---|---|---|---|
Full Report for Cushion | Detailed Parameters | Individual values #3, 4 | ° | CRN_MAIN_WIDTH_ANGLE_DEG_3, CRN_MAIN_WIDTH_ANGLE_DEG_4, CRN_MAIN_WIDTH_AZIMUTH_DEG_3, CRN_MAIN_WIDTH_AZIMUTH_DEG_4, CRN_MAIN_LENGTH_ANGLE_DEG_3, CRN_MAIN_LENGTH_ANGLE_DEG_4, CRN_MAIN_LENGTH_ |
...
AZIMUTH_DEG_3, CRN_MAIN_LENGTH_AZIMUTH_DEG_4, |
Info |
---|
Note that the |
...
Avg, Min, |
...
Max, and |
...
Dev values for these parameters were already calculated correctly |
...
before this change. All four individual measurements were taken into account. Also, the missing measurements were correctly displayed on the pictures. |
Miscellaneous
- Tolerance thresholds (modelEps, girdleEps) are now correctly interpreted during import of models from HP Pacor.
Usage of non-default values of these thresholds in HP Pacor could lead to different model built from the same contours, as compared to HPOxygen. - Inclusion clarity can now be set in HPO.
Bugfixes
- Memory leaks are fixed and memory consumption improved.
- HASP messages after the Demo license ends are fixed.
- Erroneous discount for fancy cuts is fixed.
- Capture of focus upon hovering mouse cursor over a 3D scene is fixed.
Bug that prevented the usage of Smart Recut with fixed parts (Fixed Girdle, etc.) is resolved.
Info Note that Smart Recut with fixed parts can't be used in multi-diamond solutions. - Bug that occasionally prevented SmartRecut from working in multi-diamond solutions is fixed.
- Erroneous estimation of camera FPS is fixed.
- Failure to refine models with acute angle between adjacent facets is fixed.
- Bug that caused occasional false positives in stone shift check for large stones having facets with low slopes is fixed.
...