Scanning is speeded up. This is especially noticeable at scan modes that require many additional contours. Below are the averaged scan times for two stones. The measurements were made on HP 17D with HP-1 board. Acceleration line in HPODrivers.ini
was turned off.
Round brilliant
Contours | HPP 5.6.91 | HPO 3.22.1 | HPO 3.22.12 |
---|---|---|---|
50 | 6.6 | 9.7 | 7.0 |
Quick / 100 | 8.0 | 9.4 | 8.5 |
Optimum / 200 | 14.5 | 15.8 | 14.5 |
Accuracy / 400 | 23.9 | 25.5 | 25.7 |
High Accuracy / 800 | 46.7 | 48.7 | 47.8 |
Princess
Contours | HPP 5.6.91 | HPO 3.22.1 | HPO 3.22.12 |
---|---|---|---|
50 | 14.7 | 27.7 | 15.8 |
Quick / 100 | 10.4 | 14.2 | 11.0 |
Optimum / 200 | 21.5 | 24.4 | 18.5 |
Accuracy / 400 | 31.2 | 33.5 | 28.8 |
High Accuracy / 800 | 52.4 | 55.0 | 51.1 |
Two modes of edge addition during manual adjustment of the model are now working as expected.
The users are advised to choose one of the modes depending on their confidence in the position of the missing edge.
The program, in turn, uses the degree of reliability to determine the extent to which the added edge can be altered during the refinement:
Before refinement | After refinement (high precision) | After refinement (low precision) | ||
---|---|---|---|---|
| ||||
Note the light-green added edge. | Note the refined model (cyan contours) laid over the original model (dark-green contours with light-green added edge). |
Model used: Add_edge_hard_soft.oxgz .
Note that in both cases the refinement still can affect multiple other edges, not necessarily limited to the affected facet. |
Settings for automatic actions now include the selection of label report template.
Previously the option of using custom label report templates was limited to manual generation of the label report via the right panel, and did not extend to automatic actions.
Step size control is added to the Parameters panel (unlocked mode).
The control has five positions corresponding to the following step sizes:
Position | Step size | |||
---|---|---|---|---|
Angles | mm | % | Ratio | |
1 (fine) | 0.1 | 0.01 | 0.1 | 0.001 |
2 | 0.5 | 0.05 | 0.5 | 0.005 |
3 | 2 | 0.2 | 2 | 0.02 |
4 | 5 | 0.5 | 5 | 0.05 |
5 (rough) | 10 | 1 | 10 | 0.1 |
To view the parameter panel, run Recut, select any solution, and click View → Show parameters panel. |
Unlocking the Parameters panel is not recommended. Once the parameters have been changed manually, it is no longer guaranteed that the solution fits inside the existing stone. |
Bug that occasionally caused recut solutions of the Semicut (final) algorithm to turn upside down is fixed.
Before | Now |
---|---|