Release contains:

FileVersion
HeliumPolish.exe5.6.91.1
report.dll2.10.34.1

BrilRecon.dll

1.1.24.1
ikov.dll1.1.3.9 (not changed)
Report templates2017-04-05

In this version we made the following changes:

Model building 

Algorithm for building girdle for Octagon cut is improved (Please use Brilliant method for Octagon cut).

Previous releaseCurrent release

 


Reports

Corrected mass in reports

Corrected mass is now displayed in the reports as two values, namely, with 2-digit and 4-digit precision. 

Please note that CORRECTED_MASS_2 and WEIGHT_CT bookmarks are not affected by digit precision option, so it has 2 digit precision in any case.

Reported inSectionUnitsBookmarks


All reports (all cuts)


Top


ct

CORRECTED_MASS_2 (2 digits, previously existing bookmark)

CORRECTED_MASS_4 (4 digits, new bookmark)



Lower Facet Length for Cushion

Lower Facet Length parameter is added for Cushion cuts. 

It is defined as the projected distance from the junction of the main pavilion facets to the corresponding side of the girdle, and reported separately for all four sides. 

 Reported inSectionValuesUnitsBookmarks

 

 

Full Report for Cushion

Main ParametersAvg, Min, Max, Dev at each directionBoth %(diameter) and mm

LOWER_FACET_LENGTH_0_AVG, LOWER_FACET_LENGTH_0_MIN, LOWER_FACET_LENGTH_0_MAX, LOWER_FACET_LENGTH_0_DEV,
LOWER_FACET_LENGTH_90_AVG, LOWER_FACET_LENGTH_90_MIN, LOWER_FACET_LENGTH_90_MAX, LOWER_FACET_LENGTH_90_DEV,
LOWER_FACET_LENGTH_180_AVG, LOWER_FACET_LENGTH_180_MIN, LOWER_FACET_LENGTH_180_MAX, LOWER_FACET_LENGTH_180_DEV,
LOWER_FACET_LENGTH_270_AVG, LOWER_FACET_LENGTH_270_MIN, LOWER_FACET_LENGTH_270_MAX, LOWER_FACET_LENGTH_270_DEV

Detailed ParametersIndividual values (2 at each direction)Both %(diameter) and mmLOWER_FACET_LENGTH_0_1, LOWER_FACET_LENGTH_0_2, LOWER_FACET_LENGTH_90_1, LOWER_FACET_LENGTH_90_2,
LOWER_FACET_LENGTH_180_1, LOWER_FACET_LENGTH_180_2, LOWER_FACET_LENGTH_270_1, LOWER_FACET_LENGTH_270_2

 

Crown Main Width and Crown Main Length facets for Cushion

For a non-standard Cushion cut having four Crown Main Width and four Crown Main Length facets, all four individual measurements for their slopes, azimuths, and heights are now reported.

Reported in SectionValuesUnitsBookmarks
Full Report for CushionDetailed ParametersIndividual values #3, 4°CRN_MAIN_WIDTH_ANGLE_DEG_3, CRN_MAIN_WIDTH_ANGLE_DEG_4, CRN_MAIN_WIDTH_AZIMUTH_DEG_3, CRN_MAIN_WIDTH_AZIMUTH_DEG_4,
CRN_MAIN_WIDTH_HEIGHT_PC_3, CRN_MAIN_WIDTH_HEIGHT_PC_4, CRN_MAIN_WIDTH_HEIGHT_MM_3, CRN_MAIN_WIDTH_HEIGHT_MM_4,
CRN_MAIN_LENGTH_ANGLE_DEG_3,  CRN_MAIN_LENGTH_ANGLE_DEG_4, CRN_MAIN_LENGTH_AZIMUTH_DEG_3, CRN_MAIN_LENGTH_AZIMUTH_DEG_4,
CRN_MAIN_LENGTH_HEIGHT_PC_3, CRN_MAIN_LENGTH_HEIGHT_PC_4, CRN_MAIN_LENGTH_HEIGHT_MM_3, CRN_MAIN_LENGTH_HEIGHT_MM_4
Note that the Avg, Min, Max, and Dev values for these parameters were already calculated correctly before this change. All four individual measurements were taken into account. Also, the missing measurements were correctly displayed on the pictures.

Pavilion Wing Facets

Algorithm for detection wing facets is improved:

Previous releaseCurrent Release


Facet type detection for Round Fancies

Algorithm for facet type detection is improved for Round Fancies:

Previous releaseCurrent Release

 

Girdle internal angle for Step Cut

Algorithm for girdle internal angle calculation is improved.

Previous releaseCurrent Release

 

Pavilion and crown facets type recognition on RBC

Pavilion and crown facets type bad recognition on RBC is improved:

Previous releaseCurrent Release

 

Radiant and square radiant facet height

Radiant and square radiant facet height measurement is changed:

Bug Fixes