Here you can find information about what is new in HPOxygen Server version 4.7.22.
After scanning a blocked diamond, an operator may run the allocation algorithms to check the available polishing options. As in some cases we try to optimize solutions by running the asymmetric Smart Recut allocation, it is better to have a solution which is better aligned with the previously blocked facets. When we run the Smart Recut on such a solution, we may obtain the final solution with a larger mass. The new "18. Single (Recut)" algorithm allows building solutions aligned to the already blocked facets. At least one of the solutions produced by the algorithm is normally aligned to the already blocked facets of a scanned semipolished stone.
In Galahad Mode, for the selected step it is now possible to manually select the initial facet different from the one automatically calculated by the system. Once manually set, the initial facet can then at any moment be reset to the default one.
In G1 Galahad mode, the reference line is now calculated only once for the entire polishing process (previously it was calculated for each stage separately). Also, the safe line is calculated which is the limit of safe polishing, i.e. each big facet, with the correct facet angles, can be safely polished down to the safe line without risk of damaging the future brilliant. For the crown, the reference line is displayed by a bold orange line, safe line - by a thin dotted orange line. On the left panel, on mouse over the Distance to reference line parameter, the tooltip is displayed with the information about reference and safe lines.
For the pavilion, the reference line is displayed by a bold blue line, safe line - by a thin dotted blue line. The tooltip with the detailed information is also available.
Information about reference and safe lines is also presented in the Faceting Report.
Note that if the "Girdle" or "Table" stages are included in the process, the distance to the reference line is recalculated for all other stages. |
The new "Rough Export" feature is added. This allows exporting a rough model (in most cases this will be semipolished stones) along with the set of solutions created for it. You can select one of two options:
Now you can delete existing inclusions. To delete the inclusion, on the left panel, in the Plans & Scans mode, in the Inclusions section, right-click the inclusion you want to delete, from the context menu, select Delete Inclusion.
You can delete several inclusions at once. To do so, select inclusions clicking their names holding the CTRL or SHIFT keys, then use the context or pop-up menu.
In the list of appraisers, now you can mark some appraisers as favorites: these marked appraisers will be shown as a "short list" displayed by default. The full list is available on clicking show all. To mark the appraiser as a favorite, click the star mark - it becomes highlighted. To remove the appraiser from favorites, click the start again to deselect .
The colors for the Facet Marking of the Custom Report have been changed. The overview of the updated coloring is presented in the video.
On the Galahad 1 (G1) panel, in all context menus now the icons are displayed which makes working with menus more convenient.
For the steps with substeps, now you can delete the last substep. This can be done via the context menu of the step. For convenience, the command can also be accessed in the context menu of any substep.
When trying to delete the stage, now the confirmation dialog is displayed. There you can confirm deletion of the stage or cancel deletion if you initiated it by mistake.
Now the scanning without synchronization cable is supported. On start, the system checks the synchronization cable availability. If a cable present, the scanning uses synchronization. If the cable is not found, scanning still continues - without synchronization.
Note that scanning without synchronization is slower. It is recommended to update the hardware to the newer version (HP_SMC board). |
In Galahad Compass - if a step is separated into sub-steps ("Bid Step" feature), after the direction and zero is set for the first sub-step, the system will automatically use the same direction for all following sub-steps. Previously, an operator should have defined the direction manually for each sub-step. Note that if you need to change the direction manually, you still have the ability to do that: use the Clear button and then set the new direction in a usual way.
New parameters for the report were added for different cuttings.
Parameters are calculated and exported to .ini-file report, but currently, are not displayed in any printed report. |
|
|
|
|
|
Now, for the "MyRound | GIA Facetware + MyRound" appraiser, when GIA Facetware and MyRound grades differ, both grades are displayed in the solution list simultaneously.
Grades are displayed in GIA Facetware-MyRound format, for example, "VG-GD" means that GIA Facetware grade is "VG" and MyRound is "GD". |