Here you can find information about what is new in HPOxygen Server version 4.8.20.
The Model Topology Editing Tool has been re-designed. Now the tool allows removing extra edges and drawing in their place a new configuration - all this within one operation. This includes that:
Previously, for the "13. SmartRecut (Brilliant, Oval)" algorithm the Allow Girdle Extra Facets option was trying to keep already existing extra facets of the semi-polished stone. This approach actually did not work for the stones on the early stages of polishing (rough stones) for which the extra facets were not created in spite of the selected “Allow Girdle Extra Facets” option. This prevented from getting solutions with the maximum mass caused by using the extra facets.
Now the Allow Girdle Extra Facets option has been re-designed to always create the extra facet when possible, including cases of the rough stones.
For the "MyRound | GIA Facetware + MyRound" appraiser, the new profile has been added: "MyRound_Max".
Sometimes the solutions produced using the “MyRound | GIA Facetware + MyRound” appraiser may be just a little below the mass border (like 1/2/3/4/5 carats, or 0.7, 0.9 carats). It is important to have the ability to overstep the border value. The new “MyRound_Max” profile for the “MyRound | GIA Facetware + MyRound” appraiser has been added. The parameter intervals of this profile have been extended which allows getting solutions overstepping the mass border value but still inside GIA EX boundaries.
You can find further details in the video below:
The new Lock to scan option has been implemented. The option locks the system to the Scan & Build mode and hides the Top Panel along with all the buttons.
To enable the option, go to Settings > General Settings > General section > Display tab > in the Special Environment group, select Lock to scan.
Application restart is required for the new setting to take effect. |
Now in Comparative I3D Mini View, in "Comparative" mode, short names of the main facets and their numbers are displayed both for the current and for the reference models. They are colored correspondingly.
Facet numbers are displayed only when the Facet Number check box is selected. |
Also, the main facet numbers are now displayed in the tooltip shown on mouse over the facet.
In comparative I3D Mini View, for what was selected from the plan list as the current and reference models the following information is displayed:
Now for the scan, the displayed mass will be in correspondence with the mass displayed in the plan list. This may be:
The following new stone parameters have been added:
Girdle facets average slope deviation from vertical in degrees. Calculation Thу larger area the facet with the deviation from vertical has the more it affects visually the stone. That is why the areas of the Girdle facets are included into the calculation. In User Interface Recut > Appraiser = "MyRound | GIA Facetware + MyRound" > Show Editor > the Cut tab. Reporting
|
Maximum girdle facet slope deviation from GirdleVerticality in degrees. Calculation We take every Girdle facet, calculate its deviation from vertical (A-90), then compare it to average deviation from vertical (GirdleVerticality) for this stone, then from all found values we select the maximum. It is GirdleSlopeDeviationMax. In User Interface Recut > Appraiser = "MyRound | GIA Facetware + MyRound" > Show Editor > the Symmetry tab. Reporting
|
The maximum difference between the bezel and bone heights. The parameter shows how well a Girdle is leveled in the areas of bezel and bone: the less the value is, the greater the leveling. Calculation So we measure the height of every Girdle bezel and take the maximum from obtained values, we measure the height of every Girdle bone and take the minimum from obtained values, then calculate the difference between this maximum and minimum. This is the first number. Then from Girdle bones, we take maximum, from Girdle bezels - minimum, then calculate the difference between this maximum and minimum. This is the second number. Then we take maximum from these two numbers. This is our parameter.
In User Interface Recut > Appraiser = "MyOvalOpt | MyOval" or "MyOvalPlus | MyOvalPerformanceWare > Show Editor > the Symmetry tab. Reporting
|
The maximum difference between the lengths of Girdle chords of neighboring upper and lower facets. Calculation For every pair of neighboring upper facets, we calculate the length of Girdle chords, then calculate the absolute difference between them and divide this difference by half sum of these chords. The same is done for lower facets. As we have this value for each pair of facets, we the take maximum of them. In User Interface Recut > Appraiser = "MyRound | GIA Facetware + MyRound" > Show Editor > the Symmetry tab. Reporting
|
Now you can copy data presented in the Logger Panel (available on View > Show logger (info) panel) to the clipboard. The structure of data is kept so you can paste it immediately into Excel. Prior to copying, you can:
The following fixes for the known problems and improvements have been implemented:
Table identification for fancy cuttings is improved.
Bug with the Precision panel title not updating on the cutting switch has been fixed.
Girdle Deviation from Model Building Info panel has been added to the export report data: MODEL_BUILDING_GIRDLE_ERR_VALUE_*