This "How-to" guide descibes how to edit user defined boundaries on example of appraiser which is included in release Oxygen ....

This is sample of boundaries which use likes to apply as additional limitation to GIA Facetware:

Parameter name

Minimum Value

Maximum Value

Average Table %

55

58

Average Crown Angle in degree

33

35

Average pavilion angle in degree

40.6

41.0

Average star Length %

45

50

Average Lower Length %

75

80

Average Girdle thickness bezel

2.8

3.8

Average Crown Height %

12.7

14.0

Girdle Description

THIN

MED

Culet size

0.0

0.5

Average Crown painting/Digging

-2.5

2.5

Average Pavilion Painting/Digging

-2.5

2.5

Sum of painting/digging

-3

4

 

Appraiser which is corresponds to this table is called My GIA 4/ GIA Facetware.M4. 

It includes optimization part My GIA 4 which user can find by starting strings 

[Appraiser]

Version: 7
Title: "My GIA 4"

It includes apprising part GIA Facetware.M4 which user can find by starting strings 

[Appraiser]

Version: 7
Title: "GIA Facetware.M4"

These 2 parts are editable inside file MyGIA.txt placed in folder Facetware in root folder of program.

Let's start edit boundaries:

Step-by-step guide

 

For example, user needs to change interval for Crown Angle for VG group to 30...36. It is necessary to 

  1. Open MyGIA.txt in Notepad and find apprising part GIA Facetware.M4:

    [Appraiser]

    Version: 7
    Title: "GIA Facetware.M4"
    SerialNumber: 320

    [quality]
    EX 10 RGB 0 255 0
    VG 20 RGB 255 0 255
    GD 30 RGB 255 255 0
    FR 40 RGB 255 0 0
    [end]

    [other]
    UnknownQuality: Poor 60 RGB 255 255 255

    value : t : DC_TableDiameter : stack : Ref1
    value : b : DC_CrownAngle : stack : Ref1
    value : a : DC_PavilionAngle : stack : Ref1
    value : star : DC_StarFacets : stack : Ref1
    value : lower : DC_LowerGirdleFacetLength : stack : Ref1
    value : gi : DC_GirdleThickness : stack : Ref1
    value : hc : DC_CrownHeight : stack : Ref1
    value : h : DC_GirdleThicknessValue : stack : Ref1
    value : cu : DC_Culet : stack : Ref1
    value : acp : : stack : 0
    value : app : : stack : 0
    value : sum_ap : : stack : 0

    interval : Restriction_Table : t : : : EX 55 58 VG 10 99 GD 10 99 FR 10 99 : (%) : "Intervals for Table"
    interval : Restriction_CrownAngle : b : : : EX 33 35 VG 10 90 GD 10 90 FR 10 90 : (°) : "Intervals for Crown Angle"
    interval : Restriction_PavilionAngle : a : : : EX 40.6 41.0 VG 10 90 GD 10 90 FR 10 90 : (°) : "Intervals for Pavilion Angle"
    interval : Restriction_Star : star : : : EX 45 50 VG 10 90 GD 10 90 FR 10 90 : (%) : "Intervals for Star / upper ratio"
    interval : Restriction_LowerLength : lower : : : EX 75 80 VG 50 99 GD 50 99 FR 50 99 : (%) : "Intervals for Lower length"
    interval : Restriction_GirdleBezel : gi : : : EX 2.8 3.8 VG 0 20 GD 0 20 FR 0 20 : (%) : "Intervals for gidle thickness (bezel)"
    interval : Restriction_CrownHeight : hc : : : EX 12.7 14.0 VG 5 40 GD 5 40 FR 5 40 : (%) : "Intervals for Crown Height"
    interval : Restriction_GirdleValue : h : : : EX 0.75 2.04 VG 0 20 GD 0 20 FR 0 20 : (%) : "Intervals for gidle thickness (value)"
    interval : Restriction_Culet : cu : : : EX 0 0.5 VG 0 20 GD 0 20 FR 0 20 : (%) : "Intervals for Culet"
    interval : Restriction_ACP : acp : : : EX -2.5 2.5 VG -9 20 GD -9 20 FR -9 20 : (°) : "Intervals for ACP"
    interval : Restriction_APP : app : : : EX -2.5 2.5 VG -9 20 GD -9 20 FR -9 20 : (°) : "Intervals for ASP"
    interval : Restriction_Sum_ACP_APP : sum_ap : : : EX -3.0 3.0 VG -9 20 GD -9 20 FR -9 20 : (°) : "Intervals for Sum ACP APP"

    grading : Restrictions : Restriction_Table Restriction_CrownAngle Restriction_PavilionAngle Restriction_Star Restriction_LowerLength Restriction_GirdleBezel Restriction_CrownHeight Restriction_GirdleValue Restriction_Culet : Bad :
    grading : Painting : Restriction_ACP Restriction_APP Restriction_Sum_ACP_APP : Bad :

    reserved : Calculator : "=InitData(GIA Adaptor)" : "DataValues(t,tavg,b,bavg,a,aavg,acp,paint_upp,app,paint_low,sum_ap,paint_sum)" : "Calculate parameters in GIA Adaptor appraiser"

    externalgrading : Adaptor : "GIA Adaptor" Recommended : : : : :
    grading : Main : Adaptor Calculator Restrictions Painting : Bad : Final

    [end]

    [end]


  2. Find section with "intervals" - it contains intervals for different parameters for different cut quality groups. Here user can edit intervals for EX, VG and other cut quality groups.

  3. Edit string:

Before: 

interval : Restriction_CrownAngle : b : : : EX 33 35 VG 10 90 GD 10 90 FR 10 90 : (°) : "Intervals for Crown Angle"

After: 

interval : Restriction_CrownAngle : b : : : EX 33 35 VG 30 36 GD 10 90 FR 10 90 : (°) : "Intervals for Crown Angle"

d. 

 

There is no content with the specified labels