Introduction

October release is a hotfix of a problem with inclusion shift. Also we have made automatic input data checking (background and HIG photos control) stricter.

Hotfix

The main advantage of this release is a bugfix of inclusion shift problem. On the pictures below you can see the problem and its fix. 

Automatic input data checking

The following errors can occur:

  • 2 background images (before and after scan) do not match. This means that something happened to the light setup during the scan.
    Make sure that the light setup elements do not move during the scan and the LED brightness does not change.
  • Too high background brightness. Normal background brightness is 240-245 of 255.
    In this case, decrease the LED brightness or exposure.
  • High difference between the most bright and the most dark part of background. Normally, the background should be uniform.
  • If there is some piece of background in main photo set, it is also verified. This error occures if there is enough background area around the cube and it does not match the initial background.
    This means that some changes in the lighting occur when the glass cube is installed: reflected direct LED light from the glass or holder may be the reason.